www.lg.com
P/NO : MFL69480710
INSTALLATION MANUAL
AIR
CONDITIONER
Please read this installation manual completely before installing the product.
Installation work must be performed in accordance with the national wiring
standards by authorized personnel only.
Please retain this installation manual for future reference after reading it
thoroughly.
ART COOL
Original instruction
001
ENGLISH
РУССКИЙ ЯЗЫК
Vue de la page 0
1 2 3 4 5 6 ... 24 25

Résumé du contenu

Page 1 - CONDITIONER

www.lg.comP/NO : MFL69480710INSTALLATION MANUALAIRCONDITIONERPlease read this installation manual completely before installing the product.Installatio

Page 2 - TIPS FOR SAVING ENERGY

10INSTALLATIONENGLISHBarCopper pipeClamp handleRed arrow markConeYokeHandleBar"A"InclinedInside is shiny without scratchesSmooth all roundEv

Page 3 - IMPORTANT SAFETY INSTRUCTIONS

INSTALLATION11ENGLISHCAUTIONInstallation Information. For right piping.Follow the instruction above.!Bad case- Following bending case from right to le

Page 4 - Installation

12INSTALLATIONENGLISH<Right side piping>2 Secure the cable onto the control boardwith the cable retainer.3 Tape the tubing pipe, drain hose and

Page 5 - TABLE OF CONTENTS

INSTALLATION13ENGLISHWrap the insulation materialaround the connecting portion.1 Overlap the connection pipe insulation ma-terial and the indoor unit

Page 6 - INSTALLATION PARTS

14INSTALLATIONENGLISHChecking the DrainageTo check the drainage.1 Pour a glass of water on the evaporator.2 Ensure the water flows through the drainho

Page 7 - INSTALLATION MAP

INSTALLATION15ENGLISHInstallation of filters1 Pull out the [Allergy free filter + Triple Fil-ter] from the separately packed plastic bag.2 Detach the t

Page 8 - INSTALLATION

16ENGLISHINSTALLATIONWiring Connection- Connect the wires to the terminals on the control board individually according to the outdoorunit connection.-

Page 9 - Flaring Work

17ENGLISHINSTALLATIONDIP Switch SettingIndoor UnitOutdoor UnitIn case that the products meet specific conditions, “Auto addressing” function can start

Page 10 - Connecting the Piping

18ENGLISHINSTALLATIONGroup Control SettingGroup Control 1n Wired remote controller 1 + Standard Indoor UnitsSome products have no DIP switch on PCB. I

Page 11 - Installation of Indoor Unit

19ENGLISHINSTALLATIONGNDSignal12 VSlaveSlaveMasterorDonʼt connect serial 12V lineLGAP Network SystemMasterSlaveMasterDisplay Error MessageGroup Contro

Page 12 - Indoor unit drain hose

2TIPS FOR SAVING ENERGYENGLISH• Do not cool excessively indoors. This may be harmful for your health and may consume moreelectricity.• Block sunligh

Page 13 - Wrap the insulation material

20GNDSignal12 VLGAP Network SystemFAUMasterFAUorSlaveMasterSlaveMasterMasterDisplay Error MessageDisplay Error MessageNMENGLISHINSTALLATIONGroup Contr

Page 14 - Checking the Drainage

21ENGLISHINSTALLATION2 Remote Controln Wired remote controller 2 + Indoor unit 1LGAP Network SystemMasterMasterSlaveGNDSignal12 VSlaveSlaveSlaveorDisp

Page 15 - Installation of filters

22INSTALLATIONENGLISHAccessories for group control settingIt is possible to set group control by using below accessories.Indoor unit 2 EA +Wired remot

Page 16 - Wiring Connection

INSTALLATION23ENGLISHThe A-weighted sound pressure emitted by this product is below 70 dB.** The noise level can vary depending on the site.The figure

Page 18 - Group Control Setting

[Производитель] LG Electronics Inc, Республика Корея,Кёнгсангнам, Чангвон, Сёнгсан, Ванам-ро, 84, завод Чангвон №2[Manufacturer] LG Electronics Inc. C

Page 19 - Group Control 2

IMPORTANT SAFETY INSTRUCTIONS3ENGLISHIMPORTANT SAFETY INSTRUCTIONSREAD ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.Always comply with the following pr

Page 20 - Group Control 3

4IMPORTANT SAFETY INSTRUCTIONSENGLISH• Do not install the product on a defective installation stand.- It may cause injury, accident, or damage to the

Page 21 - 2 Remote Control

TABLE OF CONTENTS5ENGLISH3 IMPORTANT SAFETY INSTRUCTIONS6 INSTALLATION PARTS6 INSTALLATION TOOLS7 INSTALLATION MAP8 INSTALLATION8 Select the best Loca

Page 22

6INSTALLATION PARTSENGLISHINSTALLATION TOOLSINSTALLATION PARTSNameQuantity ShapeInstallation plate1 EAType "A" screw5 EAType "C" s

Page 23 - Limiting concentration

INSTALLATION MAP7ENGLISHINSTALLATION MAPVinyl tape (Wide)• Apply after carrying out a drainage test.• To carry out the drainage test, remove the

Page 24

8INSTALLATIONENGLISHSelect the best Location - There should not be any heat or steam nearthe unit.- Select a place where there are no obstaclesaround

Page 25

INSTALLATION9ENGLISHOutside diameterADrill a Hole in the Wall- Drill the piping hole with a ø65 mm hole coredrill. Drill the piping hole at either the