Safety Instructions for the Installer
• A device must be provided in the electrical installation which
allows the appliance to be disconnected from the mains at all
poles with a contact opening width of at least 3 mm Suitable
isolation devices include line protecting cut-outs, fuses (screw
type fuses are to be removed from the holder), earth leakage trips
and contactors.
• In respect of re protection, this appliance corresponds to type
Y (IEC 60335-2-6). Only this type of appliance may be
installed with a high cupboard or wall on one side.
• Drawers may not be tted underneath the hob.
• The installation must guarantee shock protection.
• The kitchen unit in which the appliance is tted must satisfy the
stability requirements of IEC 68930.
• For protection against moisture, all cut surfaces are to be sealed
with a suitable sealant.
• On tiled work surfaces, the joints in the area where the hob sits
must be completely lled with grout.
• On natural, articial stone, or ceramic tops, the snap action springs
must be bonded in place with a suitable articial resin or mixed
adhesive.
• Ensure that the seal is correctly seated against the work surface
without any gaps. Additional silicon sealant must not be applied;
this would make removal more difcult when servicing.
• The hob must be pressed out from below when removed.
• Clean the work surface in the area of the cut-out.
• Sealing tape is mounted on the ceramic glass initially.