1188.. RReedd AAddjjuussttmmeenntt ((CCoommmmaanndd 22 :: vv))
G To adjust red in colour temperature.
Transmission
Data Min : 0 ~ Max : 50
*
Refer to ‘Real data mapping 2’. See page 83.
[k][v][ ][Set ID][ ][Data][Cr]
Ack
[v][ ][Set ID][ ][OK][Data][x]
1199.. GGrreeeenn AAddjjuussttmmeenntt ((CCoommmmaanndd 22 :: ww))
G To adjust green in colour temperature.
Transmission
Data Min : 0 ~ Max : 50
*
Refer to ‘Real data mapping 2’. See page 83.
[k][w][ ][Set ID][ ][Data][Cr]
Ack
[w][ ][Set ID][ ][OK][Data][x]
2200.. BBlluuee AAddjjuussttmmeenntt ((CCoommmmaanndd 22 :: $$))
G To adjust blue in colour temperature.
Transmission
Data Min : 0 ~ Max : 50
*
Refer to ‘Real data mapping 2’. See page 83.
[k][$][ ][Set ID][ ][Data][Cr]
Ack
[$][ ][Set ID][ ][OK][Data][x]
2211.. PPIIPP IInnppuutt SSeelleecctt ((CCoommmmaanndd 22 :: yy))
G To select input source for sub picture in PIP/Twin pic-
ture mode. You can also adjust input source for sub
picture using PIP INPUT button on remote control.
Transmission
Data 0 : DTV
1 : Analogue
2 : AV1
3 : AV2
4 : Component
6 : RGB-DTV
7 : RGB-PC
[k][y][ ][Set ID][ ][Data][Cr]
Ack
[y][ ][Set ID][ ][OK][Data][x]
2222.. AAbbnnoorrmmaall SSttaattee ((CCoommmmaanndd 22 :: zz))
G To recognize an abnormal state.
Transmission
Data FF : Read
Data 0: Normal (Power on and signal exist)
1: No signal (Power on)
2: Turn the monitor off by remote control
3: Turn the monitor off by sleep time function
4: Turn the monitor off by RS-232C function
5: 5V down
6: AC down
7: Turn the monitor off by Fan Alarm function
8: Turn the monitor off by Off time function
9: Turn the monitor off by Auto sleep function
a: Turn the monitor off by AV board detect
* This function is “read only”.
[k][z][ ][Set ID][ ][FF][ ][Cr]
Ack
[z][ ][Set ID][ ][OK][Data][x]
Ack
Data 1 : Inversion
4 : White Wash
2 : Orbiter
8 : Normal
[p][ ][Set ID][ ][OK][Data][x]
2233.. IISSMM MMeetthhoodd ((ooppttiioonn))
((CCoommmmaanndd 11 :: jj,, CCoommmmaanndd 22 :: pp))
G To control the ISM method. You can also adjust
ISM Method in SPECIAL menu.
It’s not available to use this function in
32/37/42LC2D models.
Transmission
[j][p][ ][Set ID][ ][Data][Cr]