LG LSN12ARMH Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Climatiseurs mobiles LG LSN12ARMH. LG LSN12ARSFH1 Owner’s Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 48
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
OWNER’S MANUAL
AIR CONDITIONER
Please read this manual carefully before operating
your set and retain it for future reference.
TYPE : WALL MOUNTED
P/No. MFL39754850
LG Electronics India Pvt. Ltd.
Regd. Office: A-27, Mohan Cooperative Industrial
Estate, Mathura Road, New Delhi-110044.
www.lg.com
MFL39754850
Vue de la page 0
1 2 3 4 5 6 ... 47 48

Résumé du contenu

Page 1 - AIR CONDITIONER

OWNER’S MANUALAIR CONDITIONER Please read this manual carefully before operatingyour set and retain it for future reference.TYPE : WALL MOUNTEDP/No. M

Page 2

Electrical Safety• This appliance must be properly grounded. To minimize the risk of electric shock, you must always plug into a grounded outlet.• Do

Page 3

Using the remote control

Page 4

12Using the remote controlWireless remote controlYou can operate the air conditioner more conveniently with the remote control. You will find thebutto

Page 5

BASIC FUNCTIONSCooling your room13MODEFollowing is the display on the displayscreen.POWERMODEPOWERFollowing is the display on the displayscreen.MODEPO

Page 6

14FANPOWERFollowing will be displayed on the displayscreen.FAN SPEEDPress FAN SPEED repeatedly to adjustthe fan speed.Select if you want natural

Page 7 - PRECAUTION

15ndPress 2 F button and check if icon is on.Press to set the desired ON time.ON–TIMER– The icon below is displayed on the display screen.

Page 8 - Prior to Operation

16ADVANCED FUNCTIONSPress POWER to turn on the power.J T COOLEAir Purification Mode(Optional)LG Air conditioner come with a variety offilters like Ant

Page 9 - Features

17ADVANCED FUNCTIONSPress POWER to turn on the power.AUTO CLEANPress POWER to turn on the power.During Auto Clean function, “Co” willbe displayed on t

Page 10 - Electrical Safety

18ADVANCED FUNCTIONSAuto changeover operationthis operation is basically heating or cooling function of the airconditioner. But during this operation

Page 11 - Using the remote control

ADVANCED FUNCTIONS19Quiet Mode Feature :In quiet mode unit display shows SL.Quiet mode will be cancelled by pressingquiet mode key again.This mode min

Page 12

(Recommended 24°C is suitable for human body)(Refer page no. 20 and 21 for details)

Page 13 - BASIC FUNCTIONS

ADVANCED FUNCTIONS208Heat pump ModelCooling ModelRoom Temp. ³ 24°C 21°C ³ Room Temp. < 24°C Room Temp. < 21°COperating mode Cooling Cooling Hea

Page 15

Plz do not press themesh with finger asshown above Caution :MAINTENANCE22(Side)(Rear)Air intakeventsAir outletventsPipingDrain Hose(Side)(Rear)Air in

Page 17

TROUBLESHOOTING24Operate the air conditioner on Air circulationmode (Refer to page 23) for 2 to 3 hours.• This will dry out the internal mechanisms.Wh

Page 18 - Auto changeover operation

Email : [email protected] ElectronicsFor any further information, please contact LGEIL BranchesBRANCH BRANCH OFFICE ADDRESS PHONE NO. / FAX NO. A

Page 22 - Caution :

TEST RUNNINGBoltTubing connectionCheck that all tubing and wiring have beenproperly connected.Check that the gas and liquid side service valvesare ful

Page 24

Gas sideLiquid sideCapHexagonal wrench2-way valve(Open)3-way valve(Close)CEvacuationSoap water methodRemove the caps from the 2-way and 3-wayvalves.Re

Page 25 - Email : [email protected]

Lo HiIndoor unitOutdoor unitManifold valveCharge hoseNitrogen gascylinder(in verticalstanding position)PressuregaugeAir purgingPressure in the system

Page 26

Tip of drain hose dipped in waterWaterleakageDitchLess than 50mm gapChecking the drainageDo not make drain piping.Form the pipingDo not raiseWaterleak

Page 27

CONNECTING THE CABLEBETWEEN INDOOR & OUTDOOR UNITConnect the cable to theoutdoor unitARemove the control cover from the unit byloosening the screw

Page 28

Connector of Reverse coil cableHeat pump 1 Tr modelREDBLACKColor of WiresLock theconnectorsproperlyTo be screwedon the channelplate ofevaporator coil.

Page 29 - Intake temperature

FLARING WORK AND CONNECTION OF PIPINGCapacity(Btu/h)Pipe Size[Torque]GAS LIQUID9K, 12K18K, 24K, 26K..1/2"[5 5kg m]..5/8"[6 6kg m]..1/4"

Page 30 - AIR PURGING

Vinyl tape(narrow)Connecting cablePipeConnectionpipeVinyl tape(wide)Wrap with vinyl tapeIndoor unit pipePlastic bandsInsulation materialVinyl tape(nar

Page 31

Vinyl tape(narrow)Connecting cablePipeConnectionpipeVinyl tape(wide)Wrap with vinyl tapeIndoor unit pipeDrain pipeConnecting cableWrap with vinyl tape

Page 32 - CONNECTING THE CABLE

FLARING WORK AND CONNECTION OF PIPINGConnection of piping-IndoorPreparing the indoor unit's piping and drainhose for installation through the wal

Page 33

FLARING WORK AND CONNECTION OF PIPINGAUse the piping kit accessory or the pipespurchased locally.Measure the distance between the indoora

Page 35 - INSTALLATION

Mount the installation plate horizontally byaligning the centerline using a level.AMount the installation plate on the wall withfour type A screws. If

Page 36

INSTALLATION OF INDOOR & OUTDOOR UNITMore than 10cm More than 10cmMore than 60cmMore than 60cmMore than 70cmRead completely, then follow step by s

Page 37

1234567891011121314Installation ToolsS.No. Required ToolsLevel GaugeScrew DriverElectric DrillHole Core Drill (Dia-70mm)Flaring Tool SetSpecified torq

Page 38 - Connection of piping

Type ‘A’ ScrewINSTALLATION PARTSInstallation parts provided with the unitType ‘A’ Screw Quantity Shape OthersType ‘A’ Screw Quantity Shape Others4Inst

Page 39 - Flaring work

6 Installation Parts provided with the Unit6 Installation Parts you must purchase7 Required Tools8101111121415171820Connecting the cable between indoo

Page 42 - INSTALLATION TOOLS

(Recommended 24°C is suitable for human body)(Refer page no. 21 and 22 owner's manual)

Page 43 - INSTALLATION PARTS

INSTALLATION MANUALAIR CONDITIONER TYPE : WALL MOUNTEDPlease read this installation manual completely before installing the product.When the power cor

Page 45

1. When this crossed-out wheeled bin symbol is attached to a means the product iscovered by the e-waste (Management and Handling) Rules, 2011.2. All e

Page 46

– Prior to operationComponentsElectrical SafetyUsing the remote control– – – Inserting BatteriesInstalling the remote control holderWireless Remote Co

Page 47

Prior to OperationPreparing for Operation1. Contact an installation specialist for installation.2. Plug in the power plug properly.3. Use a dedica

Page 48

ComponentsSymbols used in this ManualThis symbol alerts you to the risk of electric shock. This symbol alerts you to hazards that may cause harm to th